Latest Products

cprbline211NEW!
Cooper B-Line Access Security Caging System

access-cage


The Access Security Caging System has been designed to offer a modular solution to the issue of security within facilities where multiple users have access to the same zones. The assembly is designed to be mounted on standard computer raised floors and is offered in standard form to meet footprints of 600mm square tiles. Other tile sizes can be easily accommodated. Please contact the Sales Office for details.

The design allows all but the four tiles that the vertical supports sit on to be raised facilitating easy access to under floor cables and services. Additionally because of their modular design the cages can be retro fitted over existing installations to compliment existing security measures.

The Access Cage System is designed to offer 3 basic foot prints:
• 1800mm wide x 3000mm deep x approximately 2500mm high
• 2400mm wide x 3000mm deep x approximately 2500mm high
• 3000mm wide x 3000mm deep x approximately 2500mm high


The basic structure offers an integral internal light and/or CCTV monitoring mounting facility. Side panels, rear panels and doors are available in various vented patterns to enable easy configuration to meet customer specific requirements. For a quotation for e Access Caging System please contact the sales office with your specific requirements.


Call For More Info



line

cprbline211NEW!
Access Cabinet System - intelligent Advanced Cooled Enclosure (i-ACE)

i-ace
New from Cooper B-Line is i -ACE, a side mounted intelligent heat exchanger unit designed to provide closed loop 20kW cooling duty. Using proven chilled water technology, i -ACE continues Cooper B-Line’s philosophy of offering scalable solutions designed to grow with demand. i -ACE has been designed as a 300mm wide module allowing two units mounted side by side to take up one 600mm wide floor tile space. The i-ACE unit cladding can be configured to provide either left hand or right hand mounted operation. This also allows users to opt to have the cladding configured to service two adjacent enclosures, providing 50% duty to each cabinet.

  • Modular upgrade to any 42U / 47U Access Cabinet with a depth of 1000mm or more.
  • True 20kW Duty.
  • 300mm wide foot print allowing two units to mount on a 600mm tile space.
  • Single or dual cabinet configuration capability including N+1 redundancy.
  • Option to integrate internal sensors to i -BOX to provide network configurable access and remote monitoring functionality.
  • Hot swap-able fan units.
  • Colour options (Black RAL 9005 with blue trim as standard)
  • Aesthetic design that compliments the Access cabinet range.
  • Easy deployment with quick coupl ing connectors and flexible hoses.
  • Optional installation and commissioning service.
  • Fully compatible with 42U/47U height units and can be configured to suit 1000mm + depth cabinets.

i-ace-logo

Call For More Info



line
cprbline211NEW!
Cooper B-Line Access High Density Cabling Cabinet

hi-density-sml

The Access High Density Cabling Cabinet is the first cabinet designed to solve the problems of today's networking environment. It provides unique working and cabling accessibility to totally transform cabinet installation layouts, onsite installation time and on-going system management.

• Totally open construction for ease of cross-patching
• Reduced installation time
• Cabling installations made easy
• Maximum useable space
• Unrivalled working access
• Excellent cabling accessories
• Flexible panel configurations


It is the unique construction, open architecture without corner posts, which enables the quick removal of all panels & doors to completely expose the open frame for installation of cables. It is far neater, faster and user friendly for cabling installations compared with conventional cabinets. The resultant installation is much easier to maintain the bend radii especially for Category 6A cabling, and the avoidance of messy, haphazard cabling arrangements.

The Access HDC cabinet’s open frame structure provides virtually 360º total accessibility, prior to fitting panels and doors, which gives installers maximum working access and the opportunity to greatly improve installation times. The elimination of corner posts also removes the need to excessively inset 19" mounting angles, achieving maximum working space.

The unique design of enclosure, which is 900mm wide and 500mm deep, allows extra space for cable management each side of the 19’’ mounting angles. The 19’’ mounting angles are designed with finger cable management every 1U on both sides allowing for complete support of patch cords so that no U space is wasted with cable management bars.

Call For More Info



line

cprbline211NEW!
Cooper B-Line Access – 3 into 2


Cooper B-Line's Access 3 Into 2 system represents the very latest ideas in enclosure design. By utilising three sets of 19" Rails in two 800 wide bayed cabinets, an extra full 19" width of mounting facility is achieved, thus making full use of the 1600mm total cabinet width.

The 3 into 2 concept gives the significant advantage of saving space, but more importantly it cuts out the expense of an extra cabinet.

Ideal for patching applications, the 3in2 Access System is available in heights of 42U and 47U with footprints of 1600mm wide x 675mm or 875mm deep. There are a number of 19" or other mounting permutations possible, including for example, 3 sets of 19" mounting verticals across the front face, combined with 2 sets of 19" conventionally positioned vertical mounting rails in the centre of the cabinets at the rear. This enables a useful, space saving mix of patch panels and equipment in the one enclosure.

All 3in2 Access cabinet side panels, doors and fittings other than the 3in2 low profile 19"vertical mounting rails and their cross members are from the extensive standard Access range.


Call For More Info



line

aten NEW!




KL9108/916

image011 Learn More ...

line

aten NEW!
ke8220
KE8220 KVM Extender over wireless

Cable-free Presentations & Remote Server Control

The KE8220 Virtual VNC Console provides remote access to computers from a keyboard, video, and mouse (KVM) console. Access up to 4 computers at a time just as if you were sitting directly in front of them.
The KE8220 provides access to any computer on the network running AltusenVNC software. You also can “push” video from a computer running AltusenVNC to the KVM console – useful for meeting room projectors.

Learn More ...

line


Intelligent Power Management Bar

Intelligent Power Source Bar is a remote power switch that can be controlled via a web browser, telnet, modem or a console.

niroda_ipdu

One of the benefits that the Teltronix Intelligent Power source Bar has is the capability of monitoring current power usage of the outlets enabling companies to supply their customers / management with usage bills much more quickly and easily. The features also meet with energy conservation initiatives, which offer grants to companies who show that they are taking active steps to reduce their energy wastage.

Learn More...

line

EnviroRac Mk. IV

envirorac

38U or 43U enclosures, in single, double, triple or quad configurations
450mm slack racks
Plenum rear doors
Integrated 15000BTU cooling plant

System controller with:
FM200-based double knock fire control sub-system
Multi-tiered pin verified and non-static password managed access control
GSM and IP based network centric and real-time monitoring
Camera surveillance
Real-time reporting

Learn More...

line


2U Scavenger Fan Tray

2u_scavenger
cprbline211

Developed to mount into the bottom 2U of the cabinet the scavenger fan tray has been designed to pull cold air from either the floor void or from the local ambient environment.
With the top perforated area of the fan tray protruding through the front 19-inch mounting angles the unit feeds air into a chimney created by a solid door, side panels, vertical baffles and equipment mounted in the cabinet. Any unused 19-inch apertures need to be blanked off to maximise cooling efficiency.
Ideal for scenarios where the air flow to the cabinet is restricted due to either;
i) the remote location of the cabinet in relation to the CRAC unit (Computer Room Air Conditioning).
ii) where the velocity of the air from the CRAC unit is too high causing the air to bypass the cabinet location providing ineffective cold air feed.

In such cases the scavenger unit is capable of greatly improving the air feed characteristics of the cabinet.


2u_Airflow_small2u_curves_small
Click for bigger images





get_a_quote
line

EC2 Cabinet System
ec2
cprbline211

New from Cooper B-Line comes an improved and enhanced range of wall boxes designed to meet the demands of today’s market. The new design incorporates a range of features that make the product perfect for housing cabling infrastructures as well as active network and telecom equipment.
Designed with single person installation in mind, each unit is supplied fully assembled. Units can also be supplied flat packed upon request. Easy mount brackets allow the cabinet to be hung in position before being securely bolted to the wall.
The key locking fully glazed door incorporates quick release hinges for easy door removal. The hinge design also allows the door to be easily changed from left hand to right hand hinged. Optional plain steel doors are also available upon request. The design also incorporates removable key locking side panels and a screw fixed rear panel as standard. Internally each cabinet comes with two pairs of fully adjustable 19” mounting rails with each rail incorporating unit height markings. Cable entry into the EC2 wall box is via gland plated slots, positioned towards the rear of the top and bottom panel. The top and bottom panels also incorporate ventilation slots designed to allow fans to be bolted inside the cabinet for forced ventilation.

Features
  • Lockable, aesthetic glass door with quick release hinges for easy removal.
  • Fully adjustable 19” mounting angles.
  • Door can be hinged left or right.
  • Lockable, removable side panels.
  • Fast easy installation by single operator.

get_a_quote
line


cprbline211

cooper_new
Intelligent Rack Extinguisher Module

ipdu_large
Intelligent PDUs

ups_large2
UPS Systems

KVM_large2
KVM Solutions



cprbline211pdficon_large
Click to download the full 2007 Brochure (14.1Mb)
support2
Cable Support

tool2
Hand Tools
RCM+-Rack
RCM+ Rack Cable Manager








extinguisher_big

Features

Automatic smoke detection, alarm and extinguish with immediate power off to cabinet
Extendible with additional units up to 8 bayed cabinets
Supplied fully assembled. 2U 19" mounted
Visual, audible and electronic alarms
Worldwide universal AC voltage input (96-264VAC)
Option of gauge or pressure switch monitoring of canister
Inbuilt microprocessor with battery backup for i -REM


Loss of data is perhaps one of the most feared aspects of business. Losing internal records, employee records and sales records alone could cripple even the largest company to the point of
collapse. If the company also then relies on these technologies to provide a sales outlet, be it through POS terminals or Internet trading, losing these for any length of time will affect the ability to continue trading in times of crisis.

Enterprises with computer networks, IT communications and those who rely on large banks of data, house their computers, network devices and ancillary equipment in 19" floor standing racks/cabinets, i.e. a "Computer room in a Cabinet". The data is protected against viruses, the computers against power fluctuations with UPS, the excess heat by air conditioning, the security by
the latest devices, but the fire protection is often left to the room Fire Protection System. Each individual cabinet is not separately protected.

So why not let your computer room fire system handle the fire? The answer is simply the down time and disruption to business involved in doing so. Your building fire system is perfect for protecting the occupa nts of the building and the building itself, but generally has little regard for the consequences of dealing with a small fire. Even if you have expensive computer room fire extinguishing capability, this system will still flood the room with agent and clo se down all the equipment inside the room, requiring your staff to leave the room, until the agent is vented, before returning to deal with the problem.

If you have 20 racks containing data servers, this shuts 95% more of your business than need be affected by a localised fire in one rack. Cooper B-Line can now supply the i-REM, this unit is designed to protect data and equipment sited in closed separate 19" racks from the effects of a smoke threat originating within the periphery of the rack. Installed in the top 2U of the cabinet the i - REM’s microprocessor will monitor the rack for smoke, using two optical smoke detectors. Power from the rack will be removed at 3% / meter smoke obscuration. The cause of the smoke will be extinguished by filling the rack with FM200 extinguishant with a zero oxygen depletion potential.

Because this affects only the rack with the smoke, the room is safe for your staff to continue working and the rack is immediately available for engineers to repair or replace the faulty equipment, and business is resumed in the shortest possible time.

get_a_quote

top


line

cprbline211
Introducing A Better Way To Manage Your Cable With Cooper B-Line's RCM+ Rack Cable Manager

RCM+-Rack


Product Highlights :


Manage Your Cable While Managing Your Budget.

Now, installers have access to the most feature rich cable management system in the industry...introducing Cooper B-Line's RCM+.  Offering simplified cable management, a more flexible solution for all installations and a reduced total installed cost.  RCM+ has all the configurations you need for your rack supported cable management requirements.

Flexibility -

Need gates on the left, but fingers on the right?  No problem.  How about adding doors on the back?  Again, no problem!  The RCM+ open system design offers countless options and solutions to deal with issues of cable access and cable routing...like those that are created by increasing demands for faster data transmission and higher cable density.  The RCM+ incorporates an innovative modular unit concept with total interchangeability of parts over all units.  All rearrangement and modification of the cable management system is done easily in the field.  Flexibility...based on your application needs now and in the future.

Affordability -

Our RCM+ cable managers offer all the features of higher priced systems, PLUS features that aren't offered on products priced at two, three and four times as much.  Also, because of the way the RCM+ is designed, you will find significant labor savings, dramatically improved cable routing and access options.  All part of a system that can be tailored to almost any need.

Installability -

No matter what your requirement is, RCM+ can be installed in whatever configuration you need, on whatever standard 2-post rack you have or want.  The clean, simply designed appearance blends with the widest range of architecture and environments.  If you require retrofitting a cable manager to an existing rack, or if you are looking to add additional racks and accessories, RCM+ will cure all of your cable management headaches.

Features & Benefits:

360° cable routing... from anywhere, to anywhere, through anywhere

The open back design permits cable to enter or exit the cable manager at any RMU level, resulting in more direct routing to any point on the rack or an adjacent cable manager. This means less cable density, looser bundling and faster moves, adds and changes. The advantages of the open back design are amplified by the open side feature of double-sided managers.

Efficient, lower cost cable installation.

The 1/4" accessory mounting holes spaced every 1/2 RMU extend along the entire height of the RCM+.  They are an integral component of the open system design. Permitting quick attachment of a wide variety of cable management devices, they are used to support, segregate and route cables going in all directions, whether entering, leaving or passing through the manager.

Assists with data integrity by reducing cable density.

The RCM+ takes full advantage of the cable pass-through openings on the side of the new, deeper racks. The open sides created by spaced-apart mounting, allow cable to pass through the cable manager to an adjacent rack or into either cable manager through the open back.

Compatible with advancements in rack designs and rack supported components.

The RCM+ introduces a new system that consists of cable retention gates that uniquely nest under the two-piece double-hinged doors. When doors are opened, the gates provide containment, but can also be opened from either side or removed as convenience dictates. The gates can be snapped on at any location and additional gates can be added to the system.

Fast and convenient access with dynamic cable containment.

The system used to mount plastic cable support fingers is common to all cable managers in every series.  Any combination and arrangement of fingers can be installed on the mounting rails. The same universality is applied to the snap on hinges of all doors and gates. This interchangeability allows any RCM+ cable manager to be modified in the field to accommodate a broad range of applications.  This also provides for adaptability to meet any future changes required.

Field modifiable features reduce future costs.

RCM+, A Better Way To Manage Your Cable.